Health care workers are at high risk of contracting COVID-19. We estimate that SARS-Cov-2 would contaminate 25 % of our workforce during the outbreak. The face shield represents essential equipment to protect our health care team.
Unfortunately, we have a shortage of face shield due to the high demand for this equipment during the COVID-19 Outbreak.
To solve this problem, we developed the 2 Simple face shield
They are made of 0.5mm PETG sheet cut by CO2 laser
Advantages:
Files to download
How to assemble
How to Clean
Materials
- Neutral soap;
- 70 ° alcohol or polymeric biguanide;
- Apron;
- PPE's
- Procedure gloves;
- Disposable surface cleaning cloth
Procedure description
Attention: The professional must be dressed appropriately with PPE's to avoid contact and droplet directive to his skin or mucosa. He must wash his hand at the beginning and the end of the cleaning procedure ;
- Start by performing a visual inspection to detect any dirt;
- Rinse thoroughly with soap and water;
- Dry with a dry cloth;
- Moisten the cleaning cloth with 70° alcohol and / or Optigerm;
- Wipe the damp cloth on the internal and external parts;
- Put in a dry place as a shelf to dry.
Attention:
This equipment must be cleaned after each use
This equipment must be cleaned before the start of the shift and at the end of the shift.
=======================
PORTUGUESE
=======================
Materials
- Neutral soap;
- 70° alcohol or Optigerm;
- Apron;
- PPE
- Procedure gloves;
- Disposable surface cleaning cloth;
Procedure
Attention: Professionals must wash their hands at the beginning and end of cleaning the protector and be properly equipped with PPE in accordance with the contact and droplet precaution guidelines;
- Perform visual inspection to detect any residue;
- Rinse thoroughly with soap and water;
- Dry with a dry cloth;
- Dampen the cleaning cloth with 70° alcohol and/or Optigerm;
- Wipe the inside and outside with a damp cloth;
- Place in a dry place such as a drying rack.
Attention:
- This equipment should always be sanitized after each use and/or when necessary.
- This equipment must be sanitized before the start of the shift and at the end of the shift.